What was found
CRACK INDICATION IN A/C BAY AT FWD SIDE OF BS 663 UPPER ANGLE AT RBL 9. CUT AND REMOVED ATTACH ANGLE IAW SRM 57-10-10-2R-5. PERFORMED DETAILED INSPECTION OF REPAIR AREA & UNDERLYING STRUCTURE, NO DEFECTS NOTED IAW SRM 57-10-10-2R-5 REPAIR 5. HFEC IAW NDT PART 6; 51-00-00 PROC 16. NO DEFECTS NOTED. FABRICATED REPAIR PARTS IAW SRM 57-10-10-2R-5 REPAIR 5. TREATED AND PRIMED REPAIR PARTS IAW SRM 57-10-10-2R-5 REPAIR 5. INSTALLED REPAIR IAW SRM 57-10-10-2R-5 REPAIR 5. CAP SEALED FASTENERS INSIDE FUEL TANK, FILLET SEALED AND CAP SEALED REPAIR IAW SRM 57-10-10-2R-5 REPAIR 5. ELECTRICAL BOND CHECK CHECKS GOOD.