What was found
FWD WET AREA FLOOR PANEL 222BF HAS TOP PLIES PULLED. EVALUATED AND FOUND DAMAGE TP UPPER SURFACE FACE SHEET & IS REPAIRABLE IAW SRM 53-00-50-2R-0 REV. 73 TABLE 201 REPAIR 1. CLEANED AND PREPPED UPPER SURFACE IAW SRM 53-00-50-2R-1 REV. 73 STEPS 3ACEF. BONDED REPAIR PLIES IAW SRM 53-00-50-2R-1 REV. 73 STEPS 3JKLM. TAP TESTED GOOD. REPAIRED DAMAGE TO UPPER SURFACE FACE SHEET IAW SRM 53-00-50-2R-1 REV. 73 AND SRM 53-00-50-2R-0 REV. 73.