As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD CARGO R/H SIDEPLATE RBL 20 CORRODED AT FASTNERS HOLES STA. 500C-500D / REMOVED CORROSION ON SIDEPLATE IN FWD CARGO BBL20 STA 500C-500D (REMOVED .010' OF .040') FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. REMOVED AND REPLACED DAMAGED SIDEPLATE RBL 20 STA 500B+9 TO STA 500D+9 IAW SRM 53-00-53-2R-5. SEE SA-M FORM A1200847 FOR INDIVIDUAL SIGN OFFS OF WORK PERFORMED.SA-M 326 A1200847