What was found
CORROSION ON THRESHOLD SUPPORT ANGLE AT FED BS 312-328 LBL 52 WL 209. REMOVED CORROSION ON THRESHOLD SUPPORT ANGLE IAW SRM 51-10-02. FOUND TO BE OUT OF LIMITS IAW SRM 53-10-15-0I-1. REMOVED THRESHOLD SUPPORT ANGLE IAW SRM 51-40-02. LOCATED AND DRILLED NEW THRESHOLD SUPPORT ANGLE IAW DWG 141A8110, SRM 51-40-05, & SRM 51-40-08. INSTALLED NEW THRESHOLD SUPPORT ANGLE IAW DWG# 141A8110, SRM 51-40-02.