What was found
FLOOR SUPPORT CRACKED BS 312-328 LBL 45 WL 208. REMOVED CRACKED FLOOR SUPPORT IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED A NEW FLOOR SUPPORT IAW SRM 51-40-05-0G-0 AND DWG 141A5410. INSTALLED THE NEW FLOOR SUPPORT IAW SRM 51-40-02-0G-0 AND DWG 141A5400.