As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON ACB DOOR CUTOUT SUB-THRESHOLD WEB AT BS 797; RBL 22; WL 156. FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO FASTENER HOLES PER SRM 53-60-15-1A-1 FIG 103 DETAIL D. WEB WILL BE REMOVED AND REPLACED PER SRM 51-10-02-0G-0 PARAGRAPH 9.