As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
**CORROSION** ON AFT GALLEY DOOR INBOARD CREASE BEAM CORD; LOCTED BETWEEN STA. 951 AND STA. 992.8; RBL 50; AND WL 208.1 / AFT GALLEY DOOR LRW MAIN SILL R/H INNER CHORD AT BS 962-984 FOUND TO BE OUT OF LIMITS MORE THAN 3 FASTENERS IN A GROUP IAW SRM 53-70-15-1A-1. REPAIRED IAW ATS ER 20-01719 IR & SWA EA REPAIR-53EA-07833 REV 1