What was found
CORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 446.25; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS446.25'';LBL25;WL157; P/N:143A7501-1; IN AREA 2''X1''X0.018''DEEP; ORIGINAL THICKNESS 0.040'' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 PAR.4(2) FIG. 103; DETAIL A.<BR>TOOL USED: DEPTH GAGE ID:ATS2473; N/S/N; [03] REMOVED FCB FLOOR TO SIDEWALL SUPPORT BS400-BS500D; LBL25; WL157 IAW SRM 51-40-02-0G-0; [04] VERIFIED APPLICABILITY STATEMENT; DIMENSION; AND FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.; [05] CORRECTED MEASUREMENTS; [06] CORRECTION: REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS446.25'';LBL25;WL157; P/N:143A7501-183 [07] FABRICATED FLOOR TO SIDEWALL SUPPORT ZEE CHANNEL SIDEPLATE FROM BAC1496--444-7075T6 CLAD LOT#1457306-1. TREATED IAW SRM 53-00-53-2R-6 REPAIR 6. OK TO PRIME;