What was found
REFER W/O 813959 WORK INSTRUCTION NO 21-154-00695 INP. ACCOMPLISHED A DETAILED VISUAL INSPECTION AND FOUND THAT THE CRACK DAMAGE EXTENDED BEYOND THE LAST STOP DRILL ( THE CRACK LENGTH NOW IS 5.75' / REEVALUATED DAMAGE PER B737 -800 SRM 54-40-02-1A-3 ACCOMPLISHED A 0.125 INCH DIAMETER STOP DRILL AT THE END OF THE CRACKS. REINSPECTION REQUIRED EVERY WEEK FOR CRACKS LESS THAN 10 INCH ZONE 2 IAW TABLE 102 SRM 54-40-02-1A-3( THIS ITEM WILL REMAIN ON 7-DAY REINSPECT ) PER WORK INSTRUCTION 21-154-00695 -INSP)