What was found
PANEL 191CR HAS A DELAMINATION ON OUTER SKIN 32' FWD OF T/E 7' FROM O/B EDGE ; / [01] IDENTIFIED PANEL 191CR IAW SRM 53-30-70-0I-1.FIG 2; ITEM [8]. FOUND PUNCTURE AT 32'FROM AFT EDGE; 7' FROM I/B EDGE TO BE BEYOND ALLOWABLE LIMITS IAW SRM 53-30-70-1A-1.4.A.(5). REQUIRES REPAIR PER SRM 51-70-05-2R-2 IAW SRM 53-30-70-2R-1.TABLE 201.<BR>REMOVED APPROX. 1' DIA DAMAGED SKIN AND CORE IAW SRM 51-70-05-2R-2.PARA 4.A-C.; [02] VALIDATED APPLICABILITY OF SRM 51-70-05-2R-2 IAW SRM 53-30-70-2R-1.; [03] VERIFIED STEPS 1 AND 2; [04] APPLIED POTTING COMPOUND BMS5-28 TY7 LOT#AK0DP4125K; SET TO CURE BY ROOM TEMPERATURE IAW SRM 51-70-05-2R-2.PARA 4.D.NOTE; SRM 51-70-05-2R-11.PARA 4.A-B.;[12] REPAIRED DELAMINATION ON OUTER SKIN OF PANEL 191CR 32' FWD OF T/E 7' FROM O/B EDGE IAW SRM 51-70-05-2R-2 & SRM 51-70-05-2R-11.; [13] CERTIFIED WORK ACCOMPLISHED IN STEPS 11 & 12.; [14] INSPECTED REPAIR