What was found
PANEL 192AR HAS SEVERAL CRACKED FASTENER HOLES ; / [01] IDENTIFIED PANEL IAW SRM 53-40-70-0I-1 FIG 2 TABLE 2 ITEM 1. FOUND DAMAGE TO (27EA) FASTENER HOLES TO BE OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-40-70-1A-1 PARA 4.B(6)(B) AND WILL BE REPAIRED IAW SRM 51-70-05-2R-9 AS GIVEN IAW SRM 53-40-70-2R-1 PARA 4.D TABLE 202.<BR><BR>REMOVED DAMAGE AT FASTENER HOLES AND CLEANED REPAIR AREA IAW SRM 51-70-05-2R-9 PARA 4A - 4C. OK TO APPLY SLURRY TO FASTENER HOLES.