What was found
PANEL 241ZF UPPER SURFACE HAS STRAN DAMAGE ; / [01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 6 TABLE 6.<BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS SRM 53-00-50-1A-1 PARA 4F.<BR>DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-1.<BR>REMOVED ALL THROUGH INSERTS TO FACILITATE REPAIR IAW SRM 53-00-50-2R-1 PARA 3B.<BR>REMOVED DAMAGE AND CLEANED REPAIR AREA IAW SRM 53-00-50-2R-1 PARA 3C-F.; [02] VALIDATED REPAIR REFERENCES OF SRM 53-00-50-2R-1; [03] FABRICATED REPAIR PLIES USING BMS 9-3ST1581 LOT#1458851-1<BR>OK TO INSTALL IAW SRM 53-00-50-2R-1 PARA 3K; [04] VERIFIED MATERIAL ID PER SRM 53-00-50-0I-1<BR>VERIFIED DAMAGE IS OUT OF LIMITS PER SRM 53-00-50-1A-1<BR>VALIDATED REPAIR PER SRM 53-00-50-2R-1 <BR>VERIFIED DAMAGE REMOVAL AND CLEANING PER SRM 53-00-50-2R-1<BR>VERIFIED FABRICATION OF REPAIR PLIES PER SRM 53-00-50-2R-1<BR>OK TO INSTALL; [05] INSTALLED REPAIR PLIES USING BMS 8-201TY4 LOT#1459682-1<BR>VACUUM BAGGED; LEAK CHECK GOOD IAW SRM 53-00-50-2R-1 PARA 3K-L<BR>SCALE ID:ATS2275 S/N:P1662216<BR>VACUUM GAUGE:ATS2587 S/N:5432766772; [06] VERIFIED PER SRM 53-00-50-2R-1; [07] CURED REPAIR; UN-BAGGED AND TRIMMED EXCESS MATERIAL.<BR>USED THERMOMETER ID: ATS2208; S/N43300740WS<BR>IAW SRM 53-00-50-2R-1 PARA 3 M (1); [08] INSTALLED ALL NEW INSERTS WITH BMS 5-107 LOT#AK0DP4051K;<BR>CURED USING THERMOMETER ID: ATS2209 S/N 43300739WS<BR>IAW SRM 53-00-50-2R-1 PARA 3 N. AND<BR>DRAWING 147A5810-98;