What was found
SHEAR WEB TENSION STRAP CORRODED; BS1016+12; LBL8.5; WL208 ; / [01] REMOVED CORROSION ON SHEAR WEB TENSION STRAP; BS1016+12''; LBL8.5; WL208; 1.7''X1.4'' IAW SRM 51-10-02-OG-0; [02] VERIFIED CORROSION REMOVAL ON SHEAR WEB TENSION STRAP; BS1016+12''; LBL8.5; WL208; 1.7''X1.4'' IAW SRM 51-10-02-OG-0.; [03] REMOVED RIVET ON REWORKED AREA AT SHEAR WEB TENSION STRAP; BS1016+12''; LBL8.5; WL208;IAW SRM 51-40-02-OG-0; [04] UT INSPECTED BLEND AREA ON SHEAR WEB BS 1016+12; LBL 8.5; WL 208 PER NDTM PART 4; 51-00-00 PROCEDURE 2. MINIMUM REMAINING THICKNESS IS 0.034'<BR>CAL ID: ATS2031 S/N: 170515011; [05] ACCOMPLISHED WORK IN CUSTOMER CARD # TTG8Q005DRNA; [06] VERIFIED INSTALLATION TO BE PERFORMED ON CUSTOMER CARD TTG8Q005DRNA; [07] VERIFIED STEPS COMPLETE.