What was found
CORROSION ON FORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT B.S. 500A+10; L.B.L. 24; W.L. 154. ; / [01] REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT BS 500A+10; LBL 24; 1'X2' AREA; .020' DEPTH PER SRM 51-10-02. ORIGINAL THICKNESS .040'; OUT OF LIMITS PER SRM 53-00-53-1A-2; [02] VERIFIED CORROSION REMOVAL AND DAMAGE OUT OF LIMITS PER SRM.; [03] REMOVED ON FORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT BTW. BS.400 TO BS.500D IAW.SRM 51-40-02.; [04] REMOVED ON FORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT BTW. BS.400 TO BS.500D;LBL;24;WL154; IAW.SRM 51-40-02; [05] LOCATED AND DRILLED ON FORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT BTW. BS.400 TO BS.500D; L.B.L. 24;W.L.154 WITH P/N 143A7501-183;LOT.107517 I.A.W. SRM 51-40-05;DWG#143A7500.; [06] VERIFIED LOCATED AND DRILLED ON FORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT BTW. BS.400 TO BS.500D; L.B.L. 24;W.L.154 WITH P/N 143A7501-183;LOT.107517 I.A.W. SRM 51-40-05;DWG#143A7500; [07] OK TO INSTALL.; [08] OK TO INSTALL; [09] INSTALLED ON FORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT BTW BS.400 TO BS.500D LBL.24;WL 154. PER SRM 51-40-02; DWG#143A7500;143A7505; [10] REMOVED AND REPLACE ON FORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT WITH P/N 143A7501-183;LOT.107517 BTW BS.400 TO BS.500D. LBL.24. WL154 PER SRM 51-10-02; ITEM 9.C;AND DWG#143A7500;143A7505.; [11] UPDATED PARTS USAGE; [12] VERIFIED INSTALLATION OF SUPPORT; JOB COMPLETE