What was found
CORROSION ON FORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT B.S. 494-500A; R.B.L. 24; W.L. 154. ; / [01] REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT BS 500; RBL 24; 1'X2' AREA; .015' DEPTH PER SRM 51-10-02. ORIGINAL THICKNESS .032'. NO ALLOWABLE DAMAGE IN SRM; PART WILL BE REPLACED; [02] REMOVED FLOOR TO SIDEWALL SUPPORT (SHIELD) BS 494-500A RBL 24 PER SRM 51-40-02; [03] VERIFIED DAMAGE OUT OF LIMITS PER SRM.; [04] LOCATED AND DRILLED SHIELD WITH P/N 143A8126-31; LOT.1461341.IAW.SRM 51-40-05;DWG# 143A0080;OK TO APPLY TOP COAT.; [05] VERIFIED LOCATED AND DRILLED SHIELD WITH P/N 143A8126-31; LOT.1461341.IAW.SRM 51-40-05;DWG# 143A0080;OK TO APPLY TOP COAT.; [06] APPLIED TOP COAT TO SHIELD IAW.SOPM 20-41-02.; [07] VERIFIED TOP COAT APPLICATION IAW SOPM 20-41-02; [08] OK TO INSTALL.; [09] OK TO INSTALL.; [10] INSTALLED ON FWD CARGO BAY SHIELD BTW BS.494-500A;RBL.24; WL.154. PER SRM 51-40-02;DWG#143A0080.; [11] REMOVED AND REPLACED AT FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT (SHIELD) WITH P/N 143A8126-31; LOT.1461341. LOCATED BTW. BS494-500A; RBL.24; WL;154.PER SRM 51-10-02; ITEM 9.C. DWG#143A0080.; [12] VERIFIED INSTALLATION OF FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT (SHIELD) WITH P/N 143A8126-31; LOT.1461341. LOCATED BTW. BS494-500A; RBL.24; WL;154.PER SRM 51-10-02; ITEM 9.C. DWG#143A0080; [13] UPDATED PARTS USAGE; [14] JOB COMPLETE