What was found
CORROSION ON FORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT B.S. 420-440; R.B.L. 24; W.L. 154. ; / [01] REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT BS 420+10; RBL 24; 1'X2' AREA; .015' DEPTH; ORIGINAL THICKNESS .032'. NO ALLOWABLE LIMITS IN SRM; PART WILL BE REPLACED.; [02] VERIFIED DAMAGE HAS NO ALLOWABLE LIMIT PER SRM.; [03] REMOVED ON FORWARD CARGO BAY SHIELD LOCATED BETWEEN BS.420 TO BS.440 RBL.24;WL. 154 IAW. SRM 51-40-02.; [04] LOCATED AND DRILLED SHIELD WITH P/N 143A8126-21 LOT.1460664; IAW.SRM 51-40-05;DWG#143A0080. OK TO APPLY TOP COAT.; [05] VERIFIED LOCATED AND DRILLED SHIELD WITH P/N 143A8126-21 LOT.1460664; IAW.SRM 51-40-05;DWG#143A0080. OK TO APPLY TOP COAT.; [06] APPLIED TOP COAT TO SHIELD IAW SOPM 20-41-02; [07] VERIFIED TOP COAT APPLICATION IAW SOPM 20-41-02; [08] OK TO INSTALL; [09] OK TO INSTALL.; [10] INSTALLED ON FWD CARGO BAY SHIELD BTW. BS.420 -440 PER SRM 51-40-40;DWG#143A0080.; [11] REMOVED AND REPLACED ON FWD CARGO BAY SHIELD WITH P/N 143A8126-21 LOT.1460664 PER SRM.51-10-02 ITEM 9.C DWG#143A0080; [12] VERIFIED SHIELD INSTALLATION; [13] VERIFIED INSTALLATION COMPLETED