What was found
L/H AFT MOPSILL LOWER SUPPORT ANGLE FROM BS 967-986 LBL 46 WL 208 REQUIRES REPLACEMENT DUE TO CORROSION DAMAGE ; / [01] VERIFIED SRM 53-70-15-1A-1 IS APPLICABLE; [02] REMOVED CORROSION IAW SRM 53-70-15-1A-1 ON SUPPORT ANGLE FROM BS 967-986 LBL46 WL 208 AND FOUND TO BE OUT OF LIMITS. BLENDS (4 EACH)WERE 2'X.800'X .013'; 1.6'X.800'X.011; 1.5'X.800'X.014' AND 1.7'X.800'X.013'. ORIGINAL THICKNESS WAS .100' IAW DRAWING 147A8530-12.<BR>DIAL DEPTH GAUGE USED WAS ID# E9655; CAL DATE 03/2022; [03] VERIFIED - REMOVED CORROSION IAW SRM 53-70-15-1A-1 ON SUPPORT ANGLE FROM BS 967-986 LBL46 WL 208 AND FOUND TO BE OUT OF LIMITS. BLENDS (4 EACH)WERE 2'X.800'X .013'; 1.6'X.800'X.011; 1.5'X.800'X.014' AND 1.7'X.800'X.013'. ORIGINAL THICKNESS WAS .100' IAW DRAWING 147A8530-12.; [04] AWAITING ENGINEERING RESPONSE; [05] RECEIVED ENGINEERING 21-153-0197-WIP1 FOR REPAIR; [06] RECEIVED ENGINEERING 21-153-01797-WIP1 FOR REPAIR; [07] REFER TO EA 21-153-01797 SUMMARY REQUIREMENT; BARCODE: TTG8Q005QRN9.; [08] COMPLETED REPAIR PER EA 21-153-01797 WIP1; [09] VERIFIED CORRECTIVE ACTIONS #7 AND #8; [10] CARD COMPLETE