What was found
CORROSION ON FORWARD ENTRY DOOR MOP SILL AT B.S. 312-344; L.B.L. 56; W.L. 208.1. ; / [01] REMOVED CORROSION FROM FORWARD ENTRY DOOR MOP SILL BS 312-BS 344 LBL 56 WL 208.1 IN AREA OF 2'X 1' ORIGINAL MATERIAL THICKNESS 0.090' IAW SRM 51-10-02-0G-0; [02] VERIFIED REMOVAL OF CORROSION FROM FORWARD ENTRY DOOR MOP SILL BS 312-BS 344 LBL 56 WL 208.1 IN AREA OF 2'X 1' ORIGINAL MATERIAL THICKNESS 0.090' IAW SRM 51-10-02-0G-0; [03] CORROSION WAS REMOVED ON ITEM 2 ABOVE FOUND .047' MATERIAL LOSS FROM AN ORIGINAL MATERIAL THICHNESS .090' (OR 52% MATERIAL REMOVED) WHICH IS OUT OF LIMITS IAW SRM 53-10-15-1A-1 ALLOWABLE DAMAGE 1. TOOL ID USED: ATS401; [04] VERIFIED ITEM 3. OUT OF LIMITS.; [05] REMOVED FED MOPSILL IAW SRM 51-40-02; [06] LOCATED AND DRILLED NEW FED MOP SILL IAW SRM 51-40-05 AND DWG #141A112 OK TO INSTALL; [07] VERIFIED LOCATED AND DRILLED NEW FED MOP SILL IAW SRM 51-40-05 AND DWG #141A112 OK TO INSTALL GIVEN; [08] INSTALLED FED MOP SILL BETWEEN BS 270 TO BS 360 LBL 56 WL 208.1 PER SRM 51-40-02 DWG 141A8110; [09] ALL ITEM ARE COMPLETE; [10] PART INFO USAGED; [11] VERIFIED INSTALLATION FED MOP SILL BETWEEN BS 270 TO BS 360 LBL 56 WL 208.1 PER SRM 51-40-02 DWG 141A8110; [12] WORK SCOPE COMPLETE