What was found
CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 727D+7; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 727D+7; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 0.7OO' W= 0.0670' D= 0.017' ALLOWABLE MATERIAL REMAINING IS 0.023' FOUND TO BE OUT LIMITIS PER SRM 53-00-53-1A-2 TOOL USE ID: ATS1671 S/N 65093024 DATE 04/2021 DUE 01/2022; [02] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 727D+7; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 0.7OO' W= 0.0670' D= 0.017' MATERIAL REMAINING IS 0.023' FOUND TO BE OUT LIMITIS PER SRM 53-00-53-1A-2 TOOL USE ID: ATS1671 S/N 65093024 DATE 04/2021 DUE 01/2022; [03] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 727D+7; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 0.7OO' W= 0.0670' D= 0.017' MATERIAL REMAINING IS 0.023' ORIGINAL THICKNESS 0.040' FOUND TO BE OUT LIMITIS PER SRM 53-00-53-1A-2 TOOL USE ID: ATS1671 S/N 65093024 DATE 04/2021 DUE 01/2022; [04] VERIFIED OUT OF LIMITS PER SRM 53-00-53-1A-2; [05] FLOOR TO SIDEWALLL TO BE REPLACED ON FAULT NUM. TTG8Q005NLFV; [06] VERIFIED WORK TO BE ACCOMPLISHED ON FAULT# TTG8Q005NLFV