What was found
CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 767+15; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 767+15; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 1.400' W= 1' D= 0.002' MATERIAL REMAINING IS 0.038' FOUND TO BE WITHIN LIMITIS PER SRM 53-00-53-1A-2 TOOL USE ID: ATS1671 S/N 65093024 DATE 04/2021 DUE 01/2022; [02] 1. GILBERTO AGUILAR (TECHNICIAN); 04-JUL-2021 19:57 UTC <BR>REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 767+15; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 1.400' W= 1' D= 0.002' MATERIAL REMAINING IS 0.038' ORIGINAL THICKNESS 0.040' FOUND TO BE WITHIN LIMITIS PER SRM 53-00-53-1A-2 TOOL USE ID: ATS1671 S/N 65093024 DATE 04/2021 DUE 01/2022; [03] VERIFIED IN LIMITS PER SRM 53-00-53-1A-2; [04] FLOOR TO SIDEWALL TO BE REPLACED ON FAULT TTG8Q005NLFV; [05] VERIFIED PART TO BE REPLACED ON FAULT# TTG8Q005NLFV