What was found
AFT CARGO FLOOR STURCTURE; FWD SHIELD CORRODED AROUND NUTPLATE HOLES STA 767 TO 787 RBL 22 WL 156 / REMOVED CORROSION FROM AFT CARGO FLOOR STRUCTURE; FWD SHEILD AT STA 767-STA 787 IAW SRM 51-10-02-0G-0. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2; OT 0.060'; REMAIN MAT 0.045'; LOSS OF 0.815'. REMOVED AND REPLACED SHEILD IAW DWG 146A0081 REV A. PART# 146A8127-12; ATAG WN0011 APPLIED PRIMER IAW AMM 51-27-72-370-804 ' 'PN 146A8127-12