What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS312 TO BS328 AND RBL33 FWD GALLEY AND LAV ; 2021-288025 / [01] TOOL USED DIGITAL CALIPER P/N:500-197-20 S/N:11094443 DUE DATE:10-SEP-21; [02] REPLACED WEB INTERCOSTAL FLOOR STRUCTURE 1 (EA) AND FASTENERS LOCATED BTW BS312 TO BS328 AND RBL 33 FWD GALLEY AND LAV I.A.W B 737-700; SRM 51-10-02 TEM 9; SRM 51-40-02 AND DWG 141A5400 SHEET 39 REV -.; [03] REPLACED WEB INTERCOSTAL FLOOR STRUCTURE 1 (EA) AND FASTENERS LOCATED BTW BS312 TO BS328 AND RBL 33 FWD GALLEY AND LAV I.A.W B 737-700; SRM 51-10-02 TEM 9; SRM 51-40-02 AND DWG 141A5400 SHEET 39 REV -.<BR>RII ITEM.