What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 294.5 TO BS 312 AT LEVEL BL0 FWD GALLEY AND LAV ; 2021-295484 / [01] REMOVED WEB-INTERCOSTAL LOCATED BETWEEN BS294.5 TO BS 312 AT LEVEL BL0 GALLEY AND LAV. IAW B737-700 SRM 51-40-02. PERFORMED VISUAL INSPECTION ON AREA AND NOT FOUND MORE DAMAGE. EVALUATED WEB-INTERCOSTAL FOR CRACK AND NOT FOUND ALLOWABLE DAMAGE ON SRM WEB-INTERCOSTAL MUST BE REPLACED. MEASURE CRACK IS L:0.314; [02] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 294.5 TO BS 312 AT LEVEL BL0 FWD GALLEY AND LAVATORY IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DWG 141A5400 REV -; [03] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 294.5 TO BS 312 AT LEVEL BL0 FWD GALLEY AND LAVATORY IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DWG 141A5400 REV - RII