What was found
L/H VAPOR BARRIER FASTENER ATTACH HOLES ON O/B END (APPROX. 39) ARE OVERSIZED ; / PART/MATERIAL IDENTIFIED PER SRM 57-10-10-0I-2 FIG 2 TABLE 2 ITEM 4 .<BR>30' OF THE O/B EDGE BAND OVERSIZE HOLES EXCEED THE ALLOWABLE LIMITS AS GIVEN IN SRM 57-10-10-1A-2 PARA 4 D.<BR>REPAIR OVERSIZE HOLES PER MAINTENANCE LINE REQUEST.<BR>REPAIR TO BE PERFORMED IAW SRM 51-70-04-2R-10.REMOVED DAMAGE AND CLEANED REPAIR AREA;<BR>FABRICATED REPAIR PLIES USING BMS 9-3ST1581 LOT#1458851-1;<BR>OK TO INSTALL IAW SRM 51-70-04-2R-10 PARA 4B-D.; [04] INSPECTED AND VERIFIED DAMAGE REMOVAL; FABRICATION OF REPAIR PLIES AND OKAY TO INSTALL PER SRM 51-70-04-2R-10.; [05] INSTALLED REPAIR PLIES WITH BMS 8-301CL1 LOT#JH1CAA0868CURED REPAIR; UN-BAGGED AND TRIMMED EXCESS MATERIAL.<BR>IAW SRM 51-70-04-2R-10 PARA 4 F.<BR>USED HOT-BONDER ID: ATS532 S/N 15092117; VERIFIED CORRECTIVE ACTION 7 PER SRM 51-70-04-2R-10