What was found
FWD CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT IS CRACKED AT BS 500A W/L 156 LBL 24 ; / [01] REMOVED CRACKED LH FLOOR TO SIDEWALL SUPPORT FCB BS 500A W/L 156 LBL 24 IAW SRM<BR>51-40-02-0G-0 STEP 4; E; FIGURE 8; [02] FABRICATED NEW FLOOR TO SIDEWALL<BR>SUPPORT AND SPLICE OUT OF MATERIAL BAC 1496-444 7075-T6 LOT#1453146-2 IAW SRM 53-<BR>00-53-2R-5; DWG 143A7501 ID 115; SRM; 51-40-05-0G-0 SRM 51-40-08-0G-0; [03] VERIFIED; [04] VERIFIED FABRICATION OF NEW FLOOR TO SIDEWALL<BR>SUPPORT AND SPLICE OUT OF MATERIAL BAC 1496-444 7075-T6 LOT#1453146-2 IAW SRM 53-00-53-2R-5; DWG 143A7501 ID 115; SRM 51-40-05-0G-0 & SRM 51-40-08-0G-0.; [05] APPLIED A CHEMICAL CONVERSION COATING TO THE MANUFACTURED PARTS IAW SRM 51-20-01 AND SRM 53-00-53-2R-5 STEP 4.