What was found
GUSSET FOUND CRACKED AT BS500D STR-19R RBL64 ; / [01] UPON FURTHER INVESTIGATION FOUND GUSSET IS AT STR21R IAW DWG 143A7902 SH 259 REV-; [02] ALL REF ARE IN MAINTENIX/TASK INFO/ATTACHMENTS; [03] REMOVED FCB GUSSET BS 500D; STR 19RH PER SRM 51-40-02.; [04] RECEIVED LOCATED AND DRILLED NEW GUSSET P/N 143A9481-5 AT B/S 500D STR 19R RBL 64 LOT#1461912-2 IAW SRM 51-40-05 AND DWG 143A7902 REV:; [05] OK TO INSTALL; [06] EVALUATED GUSSET WITH CRACK P/N 143A9481-5 AT B/S 500D STR 19R RBL 64 ALLOWABLE DAMAGE LIMITS NOT FOUND AT SRM MUST BE REPLACED IAW SRM 51-10-02 PARAGRAPH 9; [07] UPON FURTHER INVESTIGATION VERIFIED CORRECT LOCATION FOR GUSSET P/N 143A9481-5 AT B/S 500D STR 19R IAW DWG143A7902 REV:; [08] VERIFIED. CORRECT LOCATION IS STR 19R; VERIFIED LOCATED AND DRILLED; OK TO INSTALL; [09] INSTALLED NEW GUSSET P/N 143A9481-5 AT B/S 500D STR 19R IAW DWG 143A7902 REV:; [10] INSTALLED NEW GUSSET P/N 143A9481-5 AT B/S 500D STR 19R IAW SRM 51-40-02 AND DWG 143A7902 REV:; [11] VERIFIED - INSTALLED NEW GUSSET P/N 143A9481-6 AT B/S 500D STR 19R IAW SRM 51-40-02 AND DWG 143A7902 REV:; [12] UPDATED; [13] VERIFIED ALL WORK ACCOMPLISHED THIS TASK