As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD PIT FLOOR PNL 120AF HAS CORROSION ON UPPER SURFACE ALONG FWD AND RH EDGES / EVALUATED CORROSION ON UPPER SURFACE ALONG FWD AND RH EDGES OF FWD PIT FLOOR PNL 120AF; TOTAL ACCUMLATED CORROSION DAMAGE FOUND TO EXCEED 20' MAXIMUM LENGTH ALLOWED - OUT OF LIMITS; IAW SRM 53-00-53-1A-1; FABRICATED NEW FLOOR PANEL 120AF IAW AMM 25-52-01-201-801; TO BE INSTALLED ON SA-M 565S CARD PANEL SIGN OFF SHEET ATAG A63683