CRACKED FLOOR SUPPORT UPPER ANGLE BS 380-400 LBL 1 WL 208. ; / [01] REMOVED FLOOR SUPPORT UPPER ANGLE BS380-400 LBL1; WL 208 PER SRM 51-40-02-0G-0; [02] LOCATED/DRILLED FLOOR SUPPORT UPPER ANGLE BS380-400 LBL1; WL 208 PER SRM 51-40-05-0G-0 AND DWG 143A5400. OK TO INSTALL; [03] CERTIFIED REMOVED FLOOR SUPPORT UPPER ANGLE BS380-400 LBL1; WL 208 PER SRM 51-40-02-0G-0 AND REMOVED FLOOR SUPPORT UPPER ANGLE BS380-400 LBL1; WL 208 PER SRM 51-40-02-0G-0.; [04] UPDATED MEASUREMENT TABLE.; [05] VERIFIED LOCATE & DRILL OF FLOOR SUPPORT UPPER ANGLE BS380-400; LBL1; WL 208 PER SRM 51-40-05-0G-0 AND DWG 143A5400. OK TO INSTALL GIVEN.; [06] INSTALLED FLOOR SUPPORT UPPER ANGLE BS380-400 LBL1; WL 208 PER SRM 51-40-05-0G-0 AND DWG 143A5400.; [07] CERTIFIED INSTALLED FLOOR SUPPORT UPPER ANGLE BS380-400 LBL1; WL 208 PER SRM 51-40-05-0G-0 AND DWG 143A5400.; [08] VERIFIED REPLACEMENT OF FLOOR SUPPORT UPPER ANGLE; BS 380-400; LBL 1; WL 208 PER SRM 51-40-02 AND DWG 143A5400; [09] VERIFIED ALL WORK COMPLETE THIS TASK