What was found
CRACK STIFFENER FLOOR STRUCTURE BS 540 AND BL0 TO RBL 24.5 CENTER SECTION ; 2021-319751 / [01] TOOL USED P/N: 500-197-20 S/N: 12141486 DUE DATE: 31-JAN-21; [02] REPLACED STIFFENER FLOOR STRUCTURE BS 540 AND BL0 TO RBL 24.5 CENTER SECTION I.A.W B737-700 SRM 51-10-02 PARAGRAPH 9; B737-700 SRM 51-40-02-0G-0 AND DWG:143A0060 REV B; [03] REPLACED STIFFENER FLOOR STRUCTURE BS 540 AND BL0 TO RBL 24.5 CENTER SECTION I.A.W B737-700 SRM 51-10-02 PARAGRAPH 9; B737-700 SRM 51-40-02-0G-0 AND DWG:143A0060 REV B<BR>RII