What was found
BS 663, RBL 40.5', WL 45, .700' CRACK IN CENTER TANK LOWER SKIN PANEL TO BS 663 BULKHEAD ATTACH ANGLE. VERIFIED BY NDT INSP. CUT & REMOVED DAMAGE IAW SRM 57-10-10-2R-5 REPAIR 5. PERFORMED DETAILED INSPECTION OF REPAIR AREA AND UNDERLYING STRUCTURE. NO DEFECTS NOTED IAW SRM 57-10-10-2R-5. FABRICATED REPAIR PARTS IAW SRM 57-10-10-2R-5 REPAIR 5. TREATED AND PRIMED REPAIR PARTS AND CUT EDGE IAW SRM 57-10-10-2R-5 REPAIR 5. INSTALLED REPAIR PARTS IAW SRM 57-10-10-2R-5 REPAIR 5.