What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT BS 500B+15-16 RBL 24 WL 156 ; / [01] REMOVED CORRSION FROM FCB R/H FLOOR TO SIDEWALL SUPPORT AT BS500B+15 MEASURED 3.5'L X 1.2'W AND 0.0055'DEEP FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2; FABRICATED FROM BAC1496-444 #7075T62 LOT 1457306-1; [07] VERIFIED; [08] VERIFIED FABRICATION AND LOCATE; DRILL AND COUNTERSINK OF FLOOR TO SIDEWALL SUPPORT BS 500A-500D; RBL 24; WL 157 FROM BAC1496-444 #7075T62 LOT 1457306-1 AND VERIFIED APPLICATION OF CHEMICAL CONVERSION COATING IAW SRM 51-20-01; SRM 51-40-05; SRM 51-40-06; SRM 51-40-08; DWG 143A7501 ID:3 REV:A; [09] UPDATED MEASUREMENTS; [10] UPDATED MEASUREMENTS; [11] REMOVED FWD CARGO BAY FLOOR TO ISDEWALL SUPPORT BS500A - BS500D RBL24 WL156 IAW SRM 51-40-02-0G-0; [12] APPLIED CHEMICAL CONVERSION COATING AND PRIMER IAW SRM 51-20-01-0G-0 AND SOPM 20-41-02