As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
7' CRACK FROM FASTENER TO FASTENER AT RBL 54.0; JUST ABOVE HYDRAULIC SERVICE PUMP IN GFRP WEB MATERIAL. PERFORMED INTERIM REPAIR IAW SRM 57-10-10-1A-2 2.C. (3) (A). SPEED TAPE TO BE REINSPECTEDFOR CONDITION EVERY 600 FLT CYCLES. REF EA OTHER-57EA-03738.REF W/O 433528.REPETITIVE ACTION REQUIRED /