What was found
CORROSION ON STRINGER 23 LEFT AT B.S. 311; W.L. 167. ; / [02] REMOVED DAMAGE ON STRIGER 23 LEFT AT BS 311; WL 167; AREA 1' X 1' IAW SRM 53-10-15-1A-1 ALLOWABLE DAMAGE 1.[04] REJECTED ITEM 2: 2 EA FASTENERS REQUIRE REPLACEMENT FOR HEAD DAMAGE. (FORWARD OF REMOVED FASTENER AND INBOARD OF REMOVED FASTENER). NEW FAULT RAISED.; [05] REMOVED CORROSION ON STRIGER 23 LEFT AT BS 311; WL 167; AREA 1' X 2' IAW SRM 53-10-15-1A-1 ALLOWABLE DAMAGE 1.<BR><BR>REMOVED 2 EA FASTENERS ; FORWARD OF REMOVED FASTENER AND INBOARD OF REMOVED FASTENER IAW SRM 51-40-02-0G-0; [06] VERIFIED REMOVAL OF CORROSION ON STRIGER 23 LEFT AT BS 311; WL 167; AREA 1' X 2' IAW SRM 53-10-15-1A-1 ALLOWABLE DAMAGE 1. REJECTION ITEM 1 CORRECTED ON TTG8Q005VSF2.<BR><BR>VERIFIED REMOVED 2 EA FASTENERS ; FORWARD OF REMOVED FASTENER AND INBOARD OF REMOVED FASTENER IAW SRM 51-40-02-0G-0 FOR REJECTED ITEM 2; [07] ACCOMPLISHED 10X VISUAL INSPECTION NO DEFECTS NOTED; FOUND TO BE OUT OF LIMITS PER SRM 53-10 15-1A-1 FIGURE 108 DETAIL E; FOUND TO BE OUT OF LIMITS PER SRM 53-10 15-1A-1 FIGURE 108 DETAIL E RRECTION STEP 10; [14] VERIFIED STEP 13; [15] ALL STEPS COMPLETED FOR EA 21-153-02064 IS COMPLETE; [16] VERIFIED ALL STEPS COMPLETED FOR EA 21-153-02064 IS COMPLETE;