What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT BS 470 LBL 25 WL 156 ; / [01] REMOVED FORWARD CARGO BAY L/H FLOOR TO SDIEWALL SUPPORT BS 400-500D IAW SRM 51-40-02; [02] REMOVED CORROSION FROM FCB L/H FLOOR TO SIDEWALL SUPPORT AT BS470 MEASURED 2.5'L X 1'W AND 0.055'DEEP; FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2; [03] CALIBRATED TOOL ID<BR>PIN POINT DIAL DEPTH GAUGE ATS400; [04] VERIFIED; [05] VERIFIED OUT OF LIMITS; [06] UPDATED CALIBRATED TOOL ID : PIN POINT DIAL DEPTH GAUGE ATS400 <BR>SN : UNKNOWN; [07] LOCATED; DRILLED; AND COUNTERSANK NEW FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT BS 396-500D IAW SRM 51-40-05-0G-0; SRM 51-40-08-0G-0; AND 143A7501 REV : B; [08] FABRICATED NEW REPAIR SPLICE AT FCB BS480 + 10' LBL 25 IAW SRM 53-00-53-2R-6; [09] APPLIED CHEMICAL CONVERSION COATING AND PRIMER IAW SRM 51-20-01-0G-0 AND SOPM 20-41-02; [10] OK TO INSTALL REPAIR SPLICE ON NEW FLOOR TO SIDEWALL SUPPORT; [11] OK TO INSTALL; [12] INSTALLED SPLICE TO SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0 AND SRM 53-00-53-2R-6