What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT BS 500+5 LBL 25 WL 156 ; / [01] REMOVED CORROSION FROM FCB L/H FLOOR TO SIDEWALL SUPPORT AT BS500+5 MEASURED 2.2''L X 1.1'W AND 0.0025'DEEP. WORK TO BE COMPLETED ON CUSTOMER CARD TTG8Q005MJ05; [02] CALIBRATED TOOL ID<BR>PIN POINT DIAL DEPTH GAUGE ATS400; [03] VERIFIED; [04] UPDATED <BR>CALIBRATED TOOL ID : PIN POINT DIAL DEPTH GAUGE ATS400 <BR>SN : UNKNOWN; [05] PART TO BE REPLACED ON CC# TTG8Q005MJ05 IAW SRM 53-00-53-1A-2; [06] VERIFIED; [07] REMOVED CORROSION FROM FCB L/H FLOOR TO SIDEWALL SUPPORT AT BS500+5 MEASURED 2.2''L X 1.1'W AND 0.0025'DEEP. BLEND IS OUT OF LIMITS WORK TO BE COMPLETED ON CUSTOMER CARD TTG8Q005MJ05; [08] VERIFIED; [09] REMOVED CORROSION FROM FCB L/H FLOOR TO SIDEWALL SUPPORT AT BS500+5 MEASURED 2.2''L X 1.1'W AND 0.0025'DEEP. BLEND IS OUT OF LIMITS IAW SRM 53-00-53-1A-2 WORK TO BE COMPLETED ON CUSTOMER CARD TTG8Q005MJ05; [10] VERIFIED; [11] VERIFIED JOB TASK WILL BE ACCOMPLISH ON TTG8Q005MJ05.; [12] VERIFIED JOB TASK WILL BE ACCOMPLISH ON TTG8Q005MJ05