What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT BS 500A+2 LBL 25 WL 156 ; / [01] REMOVED CORROSION FROM FCB L/H SIDEWALL SUPPORT AT BS500A+2 LBL25 MEASURED 1.75'L X 1'W AND 0.007' DEEP FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2; [02] CALIBRATED TOOL ID<BR>PIN POINT DIAL DEPTH GAUGE ATS400; [03] VERIFIED; [04] UPDATED <BR>CALIBRATED TOOL ID : PIN POINT DIAL DEPTH GAUGE ATS400 <BR>TOOL SN : UNKNOWN; [05] REPAIRED FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT IAW CUSTOMER CARD NBR : TTG8Q005MHZP; [06] VERIFIED DIMENSIONS; FOUND TO BE OUT OF LIMITS; AND JOB TASK WILL BE ACCOMPLISH ON TTG8Q005MHZP.; [07] VERIFIED DIMENSIONS; FOUND TO BE OUT OF LIMITS; AND JOB TASK WILL BE ACCOMPLISH ON TTG8Q005MHZP