What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT BS 500B+6 LBL 25 WL 156 ; / [01] REMOVED CORROSION FROM FCB L/H FLOOR TO SIDEWALL SUPPORT AT BS500B+6 MEASURED 1.9'L X 1'W AND 0.0035'DEEP; WORK TO BE COMPLETED ON CUSTOMER CARD TTG8Q005MJ05; [02] CALIBRATED TOOL ID<BR>PIN POINT DIAL DEPTH GAUGE ATS400; [03] VERIFIED; [04] PART TO BE REPLACED ON CC# TTG8Q005MJ05 IAW SRM 53-00-53-1A-2; [05] VERIFIED; [06] REMOVED CORROSION FROM FCB L/H FLOOR TO SIDEWALL SUPPORT AT BS500B+6 MEASURED 1.9'L X 1'W AND 0.0035'DEEP; BLEND IS OUT OF LIMITS WORK TO BE COMPLETED ON CUSTOMER CARD TTG8Q005MJ05; [07] VERIFIED; [08] REMOVED CORROSION FROM FCB L/H FLOOR TO SIDEWALL SUPPORT AT BS500B+6 MEASURED 1.9'L X 1'W AND 0.0035'DEEP; BLEND IS OUT OF LIMITS IAW SRM 53-00-53-1A-2 WORK TO BE COMPLETED ON CUSTOMER CARD TTG8Q005MJ05; [09] VERIFIED; [10] REMOVED CORROSION FROM FCB L/H FLOOR TO SIDEWALL SUPPORT AT BS500B+6 MEASURED 1.9'L X 1'W AND 0.0035'DEEP; BLEND IS OUT OF LIMITS IAW SRM 53-00-53-1A-2