What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT BS 500B+14 LBL 25 WL 156 ; / [01] REMOVED CORROSION FROM FCB L/H FLOOR TO SIDEWALL SUPPORT AT BS500B+14 MEASURED 1.9'L X 1'W AND 0.002'DEEP; WORK TO BE COMPLETED ON CUSTOMER CARD TTG8Q005MJ05; [02] CALIBRATED TOOL ID<BR>PIN POINT DIAL DEPTH GAUGE ATS400; [03] VERIFIED; [04] PART TO BE REPLACED ON CC# TTG8Q005MJ05 IAW SRM 53-00-53-1A-2; [05] VERIFIED; [06] REMOVED CORROSION FROM FCB L/H FLOOR TO SIDEWALL SUPPORT AT BS500B+14 MEASURED 1.9'L X 1'W AND 0.002'DEEP; BLEND IS OUT OF LIMITS WORK TO BE COMPLETED ON CUSTOMER CARD TTG8Q005MJ05; [07] VERIFIED; [08] REMOVED CORROSION FROM FCB L/H FLOOR TO SIDEWALL SUPPORT AT BS500B+14 MEASURED 1.9'L X 1'W AND 0.002'DEEP; BLEND IS OUT OF LIMITS. IAW SRM 53-00-53-1A-2 WORK TO BE COMPLETED ON CUSTOMER CARD TTG8Q005MJ05; [09] VERIFIED; [10] VERIFIED CORROSION REMOVAL IS OUT OF LIMITS AND WORK TO BE ACCOMPLISHED ON FAULT# TTG8Q005MJ05