What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT BS 500C+0-14 RBL 25 WL 156 ; / [01] REMOVED CORRSION FROM FCB R/H FLOOR TO SIDEWALL SUPPORT AT BS500C 0-14 MEASURED 1.5'L X 1.2'W AND 0.0055'DEEP PER SRM 53-00-53-1A-2 WORK TO BE COMPLETED ON CUSTOMER CARD TTG8Q005MJ25<BR><BR>CALIBRTED TOOL ID<BR>PIN POINT DEPTH GAUGE ATS2472; [02] VERIFIED CORROSION REMOVAL; [03] VERIFIED STEP 1.; [04] UPDATED MEASUREMENTS; [05] REMOVED CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT BS 500C+0-14 RBL25 MEASURED 1.5'L X 1.2'W AND 0.0055' DEEP. ORIGINAL THICKNESS .040'; REMAINING THICKNESS .0345'; FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 WORK TO BE INSTALLED ON CUSTOMER CARD TTG8Q005MJ25; [06] PIN POINT DEPTH GAUGE ATS2472 S/N UNKNOWN; [07] VERIFIED CORRECTIVE ACTION ITEMS 4;5 AND 6 COMPLETE. <BR>FOUND TO BE OUT OF LIMITS.; [08] REMOVED AND REPLACED FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT IAW CUST SYSTEM ID:TTG8Q005MJ25; [09] CALIBRATED TOOL ID <BR>PIN POINT DIAL DEPTH GAUGE ID:ATS2472 S/N:UNKNOWN; [10] VERIFIED STEP 8; [11] VERIFIED STEP 8