What was found
CORROSION ON INTERCOSTAL AT AFT CARGO BAY BS928 LBL3 WL169. ; / [01] REMOVED CORROSION ON INTERCOSTAL AT AFT CARGO BS928 LBL3 WL169.ORIGINAL THICKNESS .045'DAMAGE REMOVED .008 REMAINING THICKNESS .037' L=2'XW=1' XW=.008 DAMAGE EXCEED 10% OF ORIGINAL THICKNESS ;FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 STEP-4.C TOOL USED ID:ATS1317 S/N UNKNOWN DUE 06/2022; [02] REMOVED ON INTERCOSTAL AT AFT CARGO BS927-947.5 RBL3 WL169 IAW SRM 51-40-02; [03] VERIFIED OUT OF LIMITS; [04] LOCATED AND DRILLED NEW INTERCOSTAL AT AFT CARGO BS927-947 LBL3 WL169 IAW SRM 51-40-05 AND FABRICATED HEAT TREAT PO#830749/1.; [05] VERIFIED LOCATED AND DRILLED NEW INTERCOSTAL AT AFT CARGO BS927-947 LBL3 WL169 IAW SRM 51-40-05 AND FABRICATED AND HEAT TREAT ON PO#830749/1. OK TO APPLY CHEMICAL CONVERSION COATING AND PRIMER GIVEN.; [06] APPLIED CHEMICAL CONVERSION COATING AND PRIMER TO INTERCOSTAL (WEB) REPLACEMENT IAW SOPM 20-41-02 AND 20-43-03.; [07] VERIFIED; [08] VERIFIED APPLIED CHEMICAL CONVERSION COATING AND PRIMER TO INTERCOSTAL (WEB) REPLACEMENT IAW SOPM 20-41-02 AND 20-43-03.; [09] OK TO INSTALL INTERCOSTAL BS927-947 LBL3 WL169.; [10] VERIFIED STEP 9; [11] INSTALLED INTERCOSTAL AT ACB BS928 LBL3 WL169IAW SRM 51-40-02-0G-0 PARAGRAPH 4.B AND 7.D AND DWG 147A7500; [12] VERIFIED INSTALL; [13] VERIFIED INSTALLATION OF INTERCOSTAL AT ACB BS928 LBL3 WL169IAW SRM 51-40-02-0G-0 PARAGRAPH 4.B AND 7.D AND DWG 147A7500; [14] CARD COMPLETE