What was found
CORROSION ON SUPPORT ANGLE AT APU COMPARTMENT BS1133 LBL21; 25' BELOW LOWER HORIZONTAL DECK. ; / [01] REMOVED DAMAGE IAW SRM 51-10-02; [02] INSPECTED AND VERIFIED REMOVED DAMAGE IAW SRM 51-10-02; [03] UT THICKNESS TESTED BLENDED AREA PER 737NDT PART 4 51-00-00 PROCEDURE 2. LOWEST REMAINING THICKNESS IS .061'. ADJACENT THICKNESS IS .063'. CAL ID ATS2342 S/N 190848504; [04] APPLIED CHEMICAL CONVERSION COATING PER AMM 51-21-41-370-802 AND BMS 10-11 PRIMER PER AMM 51-21-72-370-804.; [05] NO FURTHER ACTION REQUIRED; [06] VERIFIED CONVERSION COATING AND PRIMER APPLICATION; [07] COMPLETE; [08] INSPECTION COMPLETE