What was found
CORROSION ON INTERCOSTAL AT AFT CARGO BAY BS849 LBL17 WL158. ; / [01] REMOVED CORROSION ON INTERCOSTAL AT AFT CARGO BAY B/S 849 LBL17 WL 158 DIMENSION L=2' W=1' IAW 51-10-02 PARAGRAPH 15.; [02] VERIFIED CORROSION REMOVAL; [03] UT INSPECTED BLEND IAW 737 NDTM PART 4 51-00-00 PROCEDURE 2; LOWEST THICKNESS = 0.037'<BR><BR>CAL ID ATS2031 E650; [04] EVALUATED DAMAGE ON INTERCOSTAL AT AFT CARGO BS849 LBL17 WL158 .ORIGINAL THICKNESS:.045 DAMAGE REMOVED :.008 REMAINING THICKNESS :.037 DAMAGE EXCEED 10% OF ORIGINAL THICKNESSFOUND TO BE OUT LIMITS SRM 53-00-53-1A-2.; [05] VERIFIED OUT OF LIMITS PER SRM 53-00-53-1A-2; [06] REMOVED INTERCOSTAL AT AFT CARGO BS 847-867 RBL17 WL158 IAW SRM 51-40-02.; [07] LOCATED AND DRILLED NEW INTERCOSTAL P/N 146A7505U11 AT BS 847-867 LBL17 IAW SRM 51-40-05-OG-O; DWG 146A7505 SH 9; [08] VERIFIED LOCATE AND DRILL PER SRM 51-40-05-OG-O. OK TO INSTALL INTERCOSTAL.; [09] INSTALLED NEW INTERCOSTAL AT AFT CARGO BS 847-867 LBL17 WL158 IAW SRM 51-40-02 AND DWG 146A7500 REV:A.; [10] VERIFIED; [11] VERIFIED STEP 9 INSTALLATION; [12] VERIFIED; [13] VERIFIED JOB COMPLETED