What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS747-767 LBL21 WL157. ; / [01] REMOVED CORROSION ON AFT CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT BS 747-767 IN L=3 ' X W= 1' X D= 0.08 ' FROM ORIGINAL THICKNESS OF 40'. FOUND TO BE OUT OF LIMITS. IAW. SRM 53-00-53-1A-2 FIG. 103; [02] REMOVED CORROSION ON AFT CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT BS 747-767 IN L=3 ' X W= 1' X D= 0.08 ' FROM ORIGINAL THICKNESS OF 40'. FOUND TO BE OUT OF LIMITS. IAW SRM 53-00-53-1A-2 FIG. 103. TOOLING ID: ATS 1671.S/N:65093024 DATE: 04/2021 DUE:01/2022; [03] VERIFIED OUT OF LIMITS; [04] VERIFIED OUT OF LIMITS FROM STEP 2.; [05] UPDATED P/N; [06] LOCATED; DRILLED; AND COUNTERSANK NEW ACB FLOOR TO SIDEWALL SUPPORT BS727 - BS847 LBL 21 IAW SRM 51-40-05-0G-0. SRM 51-40-08-0G-0; AND DWG 146A7502 REV : A; [07] RECEIVED NEW FLOOR TO SIDEWALL SUPPORT<BR>MPN : 146A7502-27<BR>SI# : 7532037; [08] VERIFIED; CONFIRMED LOCATE; DRILL UP AND COUNTERSINK OF NEW SUPPORT; [09] APPLIED PROTECTIVE TOP COAT OF PAINT IAW AMM 51-21-00-701.<BR>OK TO INSTALL; [10] OK TO INSTALL GIVEN; [11] INSTALLED NEW FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727+4' -BS847; LBL21; WL157 IAW SRM 51-40-02; DWG 146A7500 REV:-; DWG 146A0061 REV:-; DWG 146A7502 REV:-; [12] VERIFIED INSTALLATION OF NEW FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727+4' -BS847; LBL21; WL157 IAW SRM 51-40-02; DWG 146A7500 REV:-; DWG 146A0061 REV:-; DWG 146A7502 REV:-; [13] CARD COMPLETE