What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS747-767 RBL21 WL157. ; / [01] REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 747 - 767 IN L: 7.750' X W: 1.300' X D: 0.010 FROM ORIGINAL THINCKNESS OF 0.040'. FOUND TO BE OUT LIMITS IAW SRM 53-00-53-1A-2 FIG. 103; [02] REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS747-767 IN L: 7.750' X W: 1.300' X D: 0.010' FROM ORIGINAL THINCKNESS OF 0.040'. FOUND TO BE OUT LIMITS IAW SRM 53-00-53-1A-2 FIG 103. TOOLING PIN POINT MICROMETER ID ATS1671 SN 65093024 DATE: 04/2021 DUE: 01/2022; [03] VERIFIED OUT OF LIMITS; [04] VERIFIED OUT OF LIMITS FROM STEP 2.; [05] UPDATED MEASUREMENTS; [06] REMOVED ACB FLOOR TO SIDEWALL SUPPORT BS727-BS767 RBL 21 IAW SRM 51-40-02-0G-0; [07] LOCATED; DRILLED; AND COUNTERSANK NEW FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-05-0G-0; SRM 51-40-08-0G-0; AND DWG 146A7502 REV:A;