What was found
FWD CARGO LH TRANSITION ANGLE HAS A NUTPLATE HOLE WITH EXFOLIATION CORROSION AT STA 480+6; LBL 25. ; / [01] BLENDED AREA PER SRM 51-10-02. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. REMOVED .022 OF MATERIAL; WITH .018 REMAINING.; [02] BLENDED AREA PER SRM 51-10-02. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. REMOVED .022 OF MATERIAL; WITH .018 REMAINING.; [03] REMOVED L/H TRANSITION ANGLE FWD CARGO FROM STA 396 TO STA 500D PER SRM 51-40-02.; [04] LOCATED AND MATCH DRILLED PER SRM 51-10-02; TO BE INSTALL ON 5330-E-16461-NG