What was found
***CORROSION*** ON AFT CARGO BAY AFT BULKHEAD CENTER PANEL LOWER SUPPORT AT B.S. 947; L.B.L. 10 - R.B.L. 21; W.L. 154. / CORROSION ON AFT CARGO BAY AFT BULKHEAD CENTER PANEL LOWER SUPPORT AT BS947; LBL10-RBL21; WL154 FOUND TO BE OUT OF ALLOWABLE LIMITS DUE TO NO SRM LIMITS; REMOVED AND REPLACED AFT BULKHEAD CENTER PANEL LOWER SUPPORT AT BS947; LBL10-RBL21; WL154 IAW SRM 51-10-02-0G-0 PARA 9; SRM 51-40-02-0G-0 PARA 4(B) AND PARA 7(D); DWG 149A8110 AND DWG 149A8117