What was found
CORROSION ON TRACK AROUND FASTENER HOLE AT AFT CARGO BAY BS927+8 LBL3 WL178. / REMOVED CORROSION ON A.C.B. CARGO TRACK LBL3 BS 927+8 PER SRM 51-10-02-0G-0. BLEND MEASURED 1'X1' X0.035' DEEP. ORIGINAL MATERIAL THICKNESS IS 0.070'. DAMAGE FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2. REMOVED AND REPLACED CARGO TRACK LBL3 BS887-947 PER DWG 147A7500 SHEETS 1;2;12; AND 13; SRM 51-40-02