What was found
***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500A - BS500D RBL23 WL157. / REMOVED. CORROSION ON FLOOR TO SIDEWALL SUPPORT ON MULTIPLE AREAS FROM BS500A-BS500D RBL23 WL.157 IAW SRM 53-00-53-1A-2. BLEND FOUND. TO BE OUT LIMITS REMOVED FCB FLOOR TO SIDEWALL SUPPOR IAW SRM 51-40-02-0G. FAB. NEW. PART FLOOR TO SIDEWALL SUPPORT FROM BAC1496-44 7075T6 LOT@1435481-1 IAW SRM 51-40-15 DWG 143A7501 AND INSTALLED NEW FLOOR TO SIDEWALL SUPPORT IAW. SRM 51-40-02-0G-0 AND DWG 143A7501 59826U 07-14-2020 AND DWG 143A7500