What was found
FLOOR PANEL 241DF HAS DAMAGE AT THE CORNER ; / [01] IDENTIFIED FLOOR PANEL 241DF IAW SRM 53-00-50-0I-1 FIGURE 4. TABLE 4. <BR><BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.C.(3).(A).<BR><BR>DAMAGE IS TO BE REPAIRED IAW SRM 53-00-50-2R-1<BR><BR>REMOVED 2 EA THROUGH INSERTS TO FACILITATE REPAIR IAW SRM 53-00-50-2R-1 PARA 3.A.-B.<BR><BR>REMOVED DAMAGED FACE SHEET FROM APPROX. 2 INCH BY 2.5 INCH AREA WITH NO CONTAMINATION NOTED AND CLEANED IAW SRM 53-00-50-2R-1 PARA 3.C.-F. OKAY TO POT OPEN CORE CELLS.; [02] VERIFIED APPLICABILITY OF REPAIR TO PANEL 241DF TO BE COMPLETED IAW SRM 53-00-50-2R-1.; [03] VERIFIED MATERIAL ID PER SRM 53-00-50-0I-1<BR><BR>VERIFIED DAMAGE IS OUT OF ALLOWABLE DAMAGE LIMITS PER SRM 53-00-50-1A-1<BR><BR>VALIDATED REPAIR PER SRM 53-00-50-2R-1<BR><BR>VERIFIED DAMAGE REMOVAL WITH NO CONTAMINATION NOTED AND CLEANING PER SRM 53-00-50-2R-1<BR><BR>OK TO POT OPEN CORE CELLS; [04] APPLIED POTTING TO OPEN CORE CELLS USING BMS 5-28 TY 19 LOT# AK0DP4131K AND SET TO CURE IAW SRM 53-00-50-2R-1 PARA 3.G.-H.<BR><BR>THERMOMETER: ID - ATS2209 S/N - 4330739WS; [05] CURED POTTING COMPOUND; SANDED TO CONTOUR. FABRICATED REPAIR PLIES FROM BMS9-3 TYH2 LOT#1458851-1 IAW SRM 53-00-50-2R-1.PARA 3.H-K.(1). OK TO INSTALL