What was found
FWD CARGO COMPARTMENT FLOOR TO SIDEWALL SUPPORT HAS CORROSION BS 466-470 LBL 25 WL 156 ; / [01] UPDATED MEASUREMENTS; [02] CORROSION ON SUPPORT WAS FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO FASTENER HOLES PER SRM 53-00-53-1A-2 FIG 103 DETAIL D; [03] CORROSION ON SUPPORT WAS FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO FASTENER HOLES PER SRM 53-00-53-1A-2 FIG 103 DETAIL D. SUPPORT WILL BE REMOVED AND REPLACED ON FAULT # TTG8Q005SW8L; [04] VERIFIED CORROSION OUT OF LIMITS PER 53-00-53-1A-2; [05] VERIFIED EVALUATION FOUND TO BE OUT OF LIMITS AND REPLACE WILL BE ACCOMPLISH ON FAULT #TTG8Q005SW8L.